Waterproof ambient light sensor, no power supply specification / M761APG-PHM100SS

Waterproof illuminance sensor, no power supply required (0 to 150,000 lux) / Model number M761APG-PHM100SS

There are various outputs, both analog and digital. This sensor is used to measure the brightness of light as perceived by the human eye, and it is mainly used in places where lighting is important, such as sports venues, offices, art galleries, museums, and hospitals. Accurate measurement of lux illumination under all environmental conditions.

  • Other measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Mounted ultraviolet radiation intensity sensor / Model number WPLP-UV-01

Installed ultraviolet radiation intensity sensor

It measures the irradiance (W/m²), defined as the ratio of the radiation flux (W) incident on a surface to the unit area (m²), in the UVA / UVB / UVC spectral range. With the adoption of a new photodiode, it is insensitive to ? and infrared light. The outdoor installation type is the MC8P-PHOT3S series. ■mV signal output It measures light and radiation in the spectral regions of VIS-NIR, UVA, UVB, and UVC as illuminance (lux) or irradiance (W/m²). It is also capable of measuring the number of photons per unit time and per unit area in the photosynthetically active radiation (PAR) wavelength range of 400 to 700 nm. The WPLP series does not require an external power supply.

  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Installed radiation illuminance sensor / Model number WPLP-RAD-01

Fixed-type radiation intensity sensor

WPLP-RAD-01 measures the radiant intensity (W/m²), defined as the ratio of the radiant flux (W) incident on a surface to the unit area (m²), in the VIS-NIR spectral range (400–1050nm). These features are applicable to instruments suitable for measurements in the visible and near-infrared regions. The calibration of the probe uses the 577/579nm line of a Xe-Hg (xenon-mercury) lamp through a spectral interference filter. The outdoor installation type is the MC8P-PHOT3S series.

  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Installed illuminance sensor / Model number WPLP-PHOT-01

Illuminance (lux), defined as the ratio of luminous flux (lumens) incident on a surface to the unit area (m²), is measured.

The spectral response curve of the light measurement probe approximates the human eye's response curve known as the standard photopic curve V(λ). The difference between "WPLP-PHOT-01" and the standard photopic curve V(λ) in spectral response is calculated as error f'1. The calibration of the probe is conducted by comparing it with a photometer that has been calibrated by a primary metrology standard institution. The calibration procedure complies with CIE Document No. 69 (1987) "Method of Characterizing Illuminance Meters and Luminance Meters." Measurements are conducted by illuminating the probe with standard light A. The outdoor installation type is the MC8P-PHOT3S series.